Pre-Motive 2.0 release:

Please remember that the settings below are for legacy versions of OptiTrack Motive that predate Motive 2.0.

Broadcast frame data: ON

Local Interface: It needs to be a real IP. For example: 192.168.0.101. Do not use "localhost" if streaming from the same computer

Stream subject prefix: True
Stream Visual 3D compatible: False
Stream Markers: False
Stream unlabelled markers: False
Stream rigid bodies: False
Stream Skeletons: True
Local Rigid bodies: True
Skeleton as rigid bodies: False
Scale: 1
Bone naming convention: Motive or MotionBuilder
Up Axis: Y up
Remote trigger: False
Type: Multicast
Command port: 1510
Data port: 1511
Multicast interface: 239.255.42.99

VRPN: All off

 

Rigid Bodies Stream

Broadcast frame data: ON
Local Interface: It needs to be a real IP. For example: 192.168.0.101. Do not use "localhost" if streaming from the same computer.

Stream subject prefix: True
Stream Visual 3D compatible: False
Stream Markers: False
Stream unlabelled markers: True
Stream rigid bodies: True
Stream Skeletons: True
Local Rigid bodies: True
Skeleton as rigid bodies: False
Scale: 1
Bone naming convention: Motive or MotionBuilder
Up Axis: Y up
Remote trigger: False
Type: Multicast
Command port: 1510
Data port: 1511
Multicast interface: 239.255.42.99

VRPN: All OFF